Product name |
CCS G/BT CHAdeMO Level 3 20Kw to 60Kw Fast Wallbox DC Charger |
||
CCS PLC communication |
DIN70121 and ISO15118 |
||
EMC/Safety |
Compliant with IEC 61851-21-2:2018 IEC 61851-1:2010/EN 61851-1:2017/ IEC 61851-23:2014/IEC 61851-24 |
||
protection class |
IP55/K10 |
||
Cooling |
Forced-air cooling |
||
Mounting |
Wallbox/Floor stand |
||
Dimensions (w*D*H mm) |
680mm*320mm*720mm(1550mm) |
||
weight |
200 |
||
shell material |
Sheet metal |
||
Working enviroment
|
Ambient temperature |
-30 ~ +50°C , full power output below 50℃, Power derating 10%/ ℃ above 50℃ |
|
storage temperature |
-40 ~ +70°C |
||
working humidity |
0 ~ 95% |
||
Working altitude |
≤2000 m without derated |
||
Input parameters |
AC frequency |
45-65Hz |
|
AC voltage |
3-phases+N+PE,400±10%Vac |
||
Power factor |
>0.99 |
||
T |
Total harmonic current |
<5%(rated input)) |
|
Output parameters
|
DC Voltage accuracy |
<±0.5% |
|
Output DC voltage range |
CCS2:150-1000V |
||
Max DC output current |
CCS2:100A |
||
Max DC output power |
30KW/40kw/60kw |
||
Max system efficiency |
>94.0%(25℃,Rated input and output) |
||
HMI |
7" TFT Touch Screen LCD,RFID, Power(G) /2*Alarm(R) /2*Charging(B) panel LED |
||
Metering |
1 DC energy meter |
||
Monitor interface |
OCPP 1.6J , LAN 10M/100M and optional inner LTE wireless modem support |
||
Charging Protection
|
/ |
Overcurrent protection, Short circuit protection, Overvoltage protection, Undervoltage protection |
|
IMD |
Isulation monitoring |
||
/ |
Reverse polarity protection, Overtemperature protection |
||
RCD |
RCD-A |