Product name | CCS G/BT CHAdeMO Level 3 20Kw to 60Kw Fast Wallbox DC Charger | ||
CCS PLC communication | DIN70121 and ISO15118 | ||
EMC/Safety | Compliant with IEC 61851-21-2:2018 IEC 61851-1:2010/EN 61851-1:2017/ IEC 61851-23:2014/IEC 61851-24 | ||
protection class | IP55/K10 | ||
Cooling | Forced-air cooling | ||
Mounting | Wallbox/Floor stand | ||
Dimensions (w*D*H mm) | 680mm*320mm*720mm(1550mm) | ||
weight | 200 | ||
shell material | Sheet metal | ||
Working enviroment | Ambient temperature | -30 ~ +50°C , full power output below 50℃, Power derating 10%/ ℃ above 50℃ | |
storage temperature | -40 ~ +70°C | ||
working humidity | 0 ~ 95% | ||
Working altitude | ≤2000 m without derated | ||
Input parameters | AC frequency | 45-65Hz | |
AC voltage | 3-phases+N+PE,400±10%Vac | ||
Power factor | >0.99 | ||
T | Total harmonic current | <5%(rated input)) | |
Output parameters | DC Voltage accuracy | <±0.5% | |
Output DC voltage range | CCS2:150-1000V | ||
Max DC output current | CCS2:100A | ||
Max DC output power | 30KW/40kw/60kw | ||
Max system efficiency | >94.0%(25℃,Rated input and output) | ||
HMI | 7" TFT Touch Screen LCD,RFID, Power(G) /2*Alarm(R) /2*Charging(B) panel LED | ||
Metering | 1 DC energy meter | ||
Monitor interface | OCPP 1.6J , LAN 10M/100M and optional inner LTE wireless modem support | ||
Charging Protection | / | Overcurrent protection, Short circuit protection, Overvoltage protection, Undervoltage protection | |
IMD | Isulation monitoring | ||
/ | Reverse polarity protection, Overtemperature protection | ||
RCD | RCD-A |